ID: 00557
Gillmore cement setting time apparatus BT STGBL-1
Determines initial and final setting of cement paste using weighted needles.
Materials: Cement
- Initial setting needle mass
- 113 g
- Final setting needle diameter
- 1.06 mm
Application
The apparatus follows the transition of cement paste from a plastic state to setting. The initial and final setting needles differ in size and mass, and their action is assessed at the intervals required by the chosen procedure.
The result describes the setting behaviour of the prepared paste. It does not replace strength testing and depends on mixing and conditioning conditions.
Agree the test procedure, paste preparation and test environment. Check initial and final needle mass and diameter separately; apparatus type alone does not establish model-specific compliance.
Specifications
| Parameter | Value |
|---|---|
| Initial setting needle diameter | 2.12 mm |
| Initial setting needle mass | 113 g |
| Final setting needle diameter | 1.06 mm |
| Final setting needle mass | 453.6 g |
Scope of supply
To be confirmed for the selected model. Standard supply, grips, fixtures and options are listed separately for the selected configuration.